MRD drive RD series Helical Bevel Geared Motors
Model | RD33, RD43, RD63, RD73, RD83, RD93, RD103, RD123, RD153, RD173, RD183 |
Ratio | 5.36~14526 |
Input power | 0.12 KW~200 KW |
Output torque | Up to 50,000 N.m |
DESCRIPTION
MRD DRIVE RD series helical bevel geared motors are widely used for automotive industry, beer and beverage industry, light industry, robotized storage equipment, timber chemical industry,and board machinery, tobacco machinery, food, metallurgy, building materials industry, pulp&paper, port and environment technology, etc.
EIGENSCHAFTEN
- Adopt optimized design— modular combination, small in size
- Vertical output —Space saving
- High efficiency, up to 97% with large output torque and starts steady
- The gears are durable with long service life
- Forward and reverse operation function
- Combined with various motors
- The gearbox can be combined with mechanical variable speed driver and as a step less variable motor
- Matched with variable frequency drive to control speed and output torque
Available Versions:
RD33, RD43, RD63, RD73, RD83, RD93, RD103, RD123, RD153, RD173, RD183
Combination type: RD63RK43, RD73RK43, RD83RK63, RD93RK63, RD103RK73, RD103RK83, RD153RK73, RD153RK83, RD153RK93, RD153RK103, RD173RK93, RD173RK103, RD183RK93, RD183RK103
Technical Data:
Ratio:5.36~14526
Motor Power: 0.12 KW~200 KW
Mounting: Foot mounted, Flange mounted, Torque Arm mounted (shaft mounted)
Output Shaft: Solid shaft, Hollow shaft
Key Points of Selection:
It must be chear that the service factor fB (See the table below), output speed and motor power when selecting MRD drive RD series helical bevel helical geared motor. The service factor fB shows the application and working condition for the working machine. If you want the gears of the speed reducer be durable, the actual service factor of the working machine fBL should lower than fB, that is fBL < fB.
fB: The maxium service factor of the geared motor
fBL: Actual service factor of the working machine
Running hours per day | 4 hours | 8 hours | 16 hours | 24 hours |
Starting frequency per hour | <10 10-200 <200 | <10 10-200 <200 | <10 10-200 <200 | <10 10-200 <200 |
Uniform Load | — 0.8 1 | 0.9 1 1.1 | 1 1.1 1.2 | 1.2 1.3 1.5 |
Moderate shock load | 1 1.1 1.3 | 1.1 1.2 1.3 | 1.2 1.4 1.5 | 1.4 1.5 1.6 |
Heavy shock load | 1.3 1.4 1.5 | 1.4 1.5 1.6 | 1.5 1.6 1.7 | 1.6 1.7 1.8 |
Note: Please contact us when it is diffcult to choose fB in complicated working condition.
AVAILABLE MODELS:
RDA83-38-AM160B5-B3
RDD73-20.05-AM112B5-SZ
RDD93-22.4-ZS-B3-SZ-B
RDD93-22.4-ZS-B3-SZ-A
RDD73-20.05-YEJ2-112M4-4KW-B31-SZ-90
RDD73-20.05-YEJ2-100L2-4-3KW-B31-SZ-90
RDD73-179.67-Y8026-0.55KW-B3-A-180
RDD93-18.96-ZS-B3-B
RDD93-18.96-ZS-B3-A
RDD93-18.96-ZS-B3-SZ-SCY
RDD93-18.96-ZS-B3-SZ-SCZ
RDD83-147.32-Y100L2-4-3KW-B3-J2-A
RDDA93-34.23-AM132B5-M3
RDAF83-11.17-Y180B5-M1-AY
RDD43-39.27-YEJ90L4-1.5KW-B3-B
RDDA93-153.21-YEJ112M4-4KW-4P-B3
RDD73-20.05-YEJ2-112M4-4KW-B31-SZ-90
RDDAF-103-19.74-AM200B5-M4-J2-AY
RDD93-18.96-ZS-B3-SZ-SCZ
RDDAF-103-19.74-AM200B5-M4-J2-AY
RDZA43-15-B5(N3000)
RDF63-22.6-AM100B5-V1-AZ-ZZ
RDDA103-97.05-AM132B5-B3
RDD83-147.32-Y100L2-4-3KW-B3-J2-A
RDDAF-103-19.74-AM200B5-M4-J2-AY
RDD73-51.18-YVP-3KW-4P-B3-J2-ZZ
RDDAF-103-19.74-AM200B5-M4-J2-AY
RDD73-51.18-YVP-3KW-4P-B3-J2-ZZ
RDZA93-109-(Y112M4-4KW)-B5
RDD83-49.16-Y-4KW-4P-B3-J2-ZZ
Symbol Explanation:
DA: Foot mounted,; hollow shaft
F: B5 flange mounted; solid shaft
FV: B5 flange mounted; spline hollow shaft
AV: torque arm mounted; spline hollow shaft
ZV: B14 flange mounted; spline hollow shaft
OS: Input hole mode
—————————————————————–
D: Foot mounted; solid shaft
DV: Foot mounted; spline hollow shaft
FA: B5 flange mounted; hollow shaft
AT: Torque arm mounted; hollow shaft
ZA: B14 flange mounted; hollow shaft
ZS: Input shaft mode
Type and Designation